| Sizes |
Maximum 6m x 4.0m. |
| Tolerance |
Steel frame up to 5000mm ± 3.0mm, ± 4.0mm for frames of 5001mm to 10000mm.
Facade overall size ± 2.0mm, squareness 5.0mm. |
| Finish Options |
External high quality aggregate facing on GRC backing mix. Facing available in a wide range of finishes including brick (with mortar joints in various colours), stone (incl. sandstone, Portland, granite etc. – polished to various levels of smoothness or sand blasted), fair-face concrete, smooth or textured renders in various shades, terracotta (small, medium and large format), other bespoke finishes including patterns and mock jointing are available on request |
| Thickness |
Fabrik façade panel 18mm-23mm (comprising external facing (in range of finishes) 6-8mm thick non-structural. Internal backing (GRC) minimum 12-15mm thick). Overall complete build-up thickness (i.e. Fabrik façade, cavity, insulation and Kingframe) is flexible depending on application, insulation thickness required and wind loadings etc. Typical total thickness will range from 220mm to 340mm |
| Construction |
Steel – BS EN 10147 Grade S390 GD, C Section Galvanised.
Insulation – Kingspan Kooltherm K15 Rainscreen manufactured from closed cell rigid phenolic insulation
core, incorporating foil facings on both sides.
Facade Fasteners – stainless steel flex anchors.
Fastenings – self drill/tap type fasteners and high strength steel rivets are zinc plated with an organic coating.
Facade – a composite material mix, comprising a cement and silica sand matrix reinforced with chemical
resistant glass fibres, to produce a high compressive strength, lightweight concrete with
enhanced tensile and flexural properties. |
| Structural |
Non Load Bearing. |
| Service Holes |
Options available, please contact Kingspan Technical Department. |
| Openings |
Doors, windows and other fixing ancillaries can be incorporated. |
| Construction Methods |
Single Storey – recessed & face-fixed
Multi Storey – face-fixed
Spandrel
(continuous windows) – dado, intermediate floors and eaves – recessed or face-fixed
Dado wall – face-fixed |
| Durability |
60 year design life. |
| |
|
Performance
(dependent on system selected) |
Fire – Please contact Kingspan Technical Department.
Acoustic – Please contact Kingspan Technical Department.
Weight – 62.50 kg/m2 to 64.70 kg/m2
Thermal – 0.20 – 0.35 W/m2K |
| Accreditations |
BRE Certification and International GRC Association Specification cured and tested. |
| Fittings & Accessories |
Self drill/tap type fasteners and
high strength steel rivets are zinc
plated with an organic coating. |
| Standards & Approval |
Conforms to Building Regulations, Standards and certificates:
• Approved Document A: Structure (England & Wales)
• Approved Document B: Fire (England & Wales)
• Approved Document E: Resistance to the Passage of Sound (England & Wales)
• Approved Document Parts L1 and L2: Conservation of Fuel & Power (England & Wales)
• DfES Building Bulletin (BB93) - Acoustic Design of Schools
• NHS Estates Technical Memorandum (HTM) 2045
• Energy Performance of Buildings Directive
• Building Standard Part D: Structural Fire Precautions (Scotland)
• Building Standard Part H: Resistance to the Transmission of Sound (Scotland)
• Building Standard Part J: Conservation of Fuel & Power (Scotland)
• Technical Guidance Document Part A: Structure (Ireland)
• Technical Guidance Document Part B: Fire Safety (Ireland)
• Technical Guidance Document Part D: Materials & Workmanship (Ireland)
• Technical Guidance Document Part E: Sound (Ireland)
• Technical Guidance Document Part F: Ventilation (Ireland)
• Technical Guidance Document Part L: Conservation of Fuel & Energy (Ireland) |
| Delivery & Site
Installation |
Delivery – Dependent on individual panel dimensions. Panels are typically delivered to site on low loader or flat bed trailers with customised racking.
Site Handling – Hoist or site crane depending on application.
Installation – Via Approved Installers.
Fixing – Tech screws and bolts typically M12 express anchors. |
| Labelling |
Panels are labelled with a unit reference no. which indicates location on site. |
| External Jointing |
Appropriate silicone mastic applied in accordance with manufacturers instructions. |
| Cleaning |
Fitted panels are cleaned of site dirt after silicone mastic has cured. |
Insulation & Internal
Plaster Boarding |
For BRE Certification 12.5mm or 15mm Gypsum Board or 12.5mm Fermacell can be used.
Other non BRE Certification options are available supplied by others. |
Notes